Function:
|
Engine Exhaust gas flow rate measurement
|
Accuracy:
|
± 2.5 % of reading or ± 1.5% of full scale
|
Outputs:
|
Analogue (0 - 10V, user configurable scaling), RS-232 and LAN
|
Materials in Gas Contact:
|
304 stainless steel, copper gaskets, PTFE (low temperature), Thermiculite (High temperature)
|
Purge Air Gas:
|
Compressed Air, 10 bar maximum (regulator not included)
|
Power (Interface unit):
|
230VAC, 50 Hz : 600 W or 115VAC, 50/60 Hz : 600 W
|
Dimensions (Interface):
|
219 mm (H) : 370 mm (W) : 330 mm (D) - Dimensions exclude fittings
|
Weight:
|
14 Kg
|
Flow Tubes:
|
Type
A - 2 m3/min, B - 4.5m3/min, C - 10m3/min, D - 15 m3/min, E 20 m3/min, F - 30 m3/min, G - 45 m3/min, H - 65 m3/min |
Tube Connections:
|
Tube connections can be adapted to suit engine exhaust pipes.
|
Exhaust Pressure:
|
± 10 kPa gauge.
|
Remote Display:
|
For local display of flow rate, flow tube type and local control of Standby, Zero, Purge and Measure modes.
|